© ARCO STARTING & CHARGING SPECIALISTS 39 TILT-TRIM MOTOR SOLENOIDS WIRE WOUND FIELD MOTORS TECH TIPS Motor Running In The Up Direction When the tilt-trim switch is in the up, position solenoid #2 is energized and battery positive voltage is supplied to the blue wire making the motor run in the up direction. This raises the outdrive or outboard motor. Motor Running In The Down Direction When the tilt-trim switch is in the down position, solenoid #1 is energized and battery positive voltage is supplied to the green wire making the motor run in the down direction. This lowers the outdrive or outboard motor.