| Author |
Message |
   
Francisco Tudela
New member Username: tudelac
Post Number: 1 Registered: 08-2009
| | Posted on Saturday, August 08, 2009 - 02:39 pm: |
|
The other day, i had to use the emergency air shutdown to turn off my engine due to a solenoid starter problem. I changed the strater and put the reopened the emergency air shutoff valve. When i tried to restat, the engine turned over and white smoke came out of the turbo but the engine didnt start. What should i do or might be the problem? |
   
Jimmy Graves
Member Username: jimg4652
Post Number: 38 Registered: 11-2008
| | Posted on Saturday, August 08, 2009 - 04:49 pm: |
|
Did you make sure your new starter was the same rotation as your old one? How many times did you try to start it, and how long did you let the engine spin over? |
   
Francisco Tudela
New member Username: tudelac
Post Number: 2 Registered: 08-2009
| | Posted on Saturday, August 08, 2009 - 08:10 pm: |
|
We tried to start the engine four times for at least 10 seconds. We even tried to add ether. We think the starters are rotating in the same direction. |
   
MARVIN PIERCE
Advanced Member Username: marv
Post Number: 316 Registered: 09-2001
| | Posted on Sunday, August 09, 2009 - 05:55 pm: |
|
MIT BE THE EMERGENCY SHUTDOWN DID NOT RESET OR THE FLAPPER PLATE BROKE OFF. |