| Author |
Message |
   
ged mellish
New member Username: ged
Post Number: 1 Registered: 05-2008
| | Posted on Sunday, May 18, 2008 - 04:14 am: |
|
Hello again. posted a question yesterday as Gerald . but have joined the forum now. so new user name Ged. Mercruiser 502 i have two temp senders in the therm housing, i assume one is for the gauge and the other is for the alarm, is this the case ?. if so are they a different type of sender to each other ? Ged |
   
Bt Doctur
Advanced Member Username: bt_doctur
Post Number: 309 Registered: 06-2006
| | Posted on Sunday, May 18, 2008 - 10:39 am: |
|
I think one is a sender that works on the ohm`s and the other is a switch type to set the alarm.(on-off) |
   
Guy Gaspar
Senior Member Username: guyjg
Post Number: 2054 Registered: 08-2006
| | Posted on Sunday, May 18, 2008 - 11:03 am: |
|
That was too easy BD! |
   
Bondo
Senior Member Username: bondo
Post Number: 1019 Registered: 12-2006

| | Posted on Sunday, May 18, 2008 - 11:44 am: |
|
"if so are they a different type of sender to each other ?" Ayuh,..... 1 is a variable resistence sender,+ the other is a Make, or Break sensor..... |
   
ged mellish
New member Username: ged
Post Number: 2 Registered: 05-2008
| | Posted on Sunday, May 18, 2008 - 02:55 pm: |
|
thanks for that. think the wireing colours are brown white tracer for temp gauge, and brown for alarm ?,think i,ll change mine. just got to source some now. its hard over here boys you would,nt believe it,all the best G |