| Author |
Message |
   
Ned Dixon
Member Username: ned_dixon
Post Number: 21 Registered: 02-2009
| | Posted on Tuesday, October 27, 2009 - 07:50 pm: |
|
Friend called with this. Unknown year 50 horse johnson, model # J50PLS0SC. They have to pump primer bulb to keep it running, buzzer went off multiple times, VRO still hooked up. Any thoughts on why the gas isn't flowing, other ideas? Thanks in advance! |
   
jwbmarine
Senior Member Username: jwbmarine
Post Number: 5070 Registered: 11-2005
| | Posted on Tuesday, October 27, 2009 - 08:00 pm: |
|
best i can figure,..it is an --05--,...u either have alot of air leaks,'rare',obstructions,..or u have a failed OMS pump....fuel/oil pump.... |
   
Ned Dixon
Member Username: ned_dixon
Post Number: 22 Registered: 02-2009
| | Posted on Tuesday, October 27, 2009 - 09:33 pm: |
|
Thanks - As always, your help and advice are much appreciated. |
   
Morten Ringvold
Senior Member Username: haffiman37
Post Number: 4317 Registered: 04-2006

| | Posted on Tuesday, October 27, 2009 - 11:18 pm: |
|
Note that if you need to keep the engine running by using the bulb as pump, and VRO is hooked up, engine is getting NO oil. Probably the reason for the alarm. Until problem solved, at least add 2% oil to the fuel! |
   
Ned Dixon
Member Username: ned_dixon
Post Number: 23 Registered: 02-2009
| | Posted on Wednesday, October 28, 2009 - 09:40 pm: |
|
Good point, I'll pass that on. I appreciate the help! |
|